Showing results: 526 - 540 of 2630 items found.
-
Ametek Scientific Instruments
Potentiostats control a voltage and measure a resulting current. The Control Amplifier outputs power to the counter electrode (also called auxiliary electrode). A feedback loop is established to control the cell potential between the reference and working electrode. This voltage is measured by the input electrometer, that has a high impedance. This current is then measured between the working and counter electrodes while this potential is maintained at the working electrode and reference electrode.
-
TCS-1 -
JFM Engineering
The TCS-1 Trickle Charger is a low current, constant current/constant voltage charger It can be used to trickle charge Nickel-Cadmium and Lead-Acid batteries. Its primary use is to maintain the batteries at full charge while the batteries are in storage (to compensate for the battery self-discharge). Adjustable float voltage and maximum charging current. Usable on batteries up to 100A-Hr The TCS-1 can also be used as a full charger for batteries of up to 5.0A-hr (@ C/10).
-
Algodue elettronica
Additional voltage and current measurement channels in comparison with other standard three-phase devices.Current inputs for CTs or for clamps to grant an accurate current measurement.Continuous monitoring of the power quality and Class A certified measurements for voltage characteristics.Simultaneous recording of events, Min/Avg/Max LOG and energy counters.Several possibilities for instrument data transmission: Ethernet, Modbus TCP, 3G network.User-friendly instrument web interface with multilingual pages.
-
Digatron Power Electronics
Electronic loads are required for testing fuel cells such as PEMFC, AFC, PAFC, MCFC, SOFC. These electronic loads are designed either in IGBT technology with power, current and voltage ranges according to specific requirements or in transistor technology. Electronic loads in IGBT technology are designed for high voltage ranges up to 900 V, current ranges up to 1000 A, and power ranges up to 480 kW.
-
AMPI-530 -
Amperis sl
Measurement of short-circuit loop ; Testing of differential, general and selective protections for differential current ; Measurement of insulation resistance ; Up to 10GΩ ; Voltages: 50 V, 100 V, 250 V, 500 V, 1000 V ; Measurement of earth resistance ; Bi-directional continuity test on PE cables, phase sequence ; Measurement and recording of voltage, frequency, alternating current, cosϕ, power, harmonics and THD
-
N8740A -
Keysight Technologies
Keysight's basic DC power supplies offer essential features for a tight budget. The Keysight N8740A is a 150 V, 22 A, 3300 W, single output power supply in a small 2U package. It offers flexible AC input options, analog/resistance control of output voltage and current, as well as parallel and series connection of multiple supplies to achieve more output current or voltage respectively.
-
N8742A -
Keysight Technologies
Keysight basic DC power supplies offer essential features for a tight budget. The Keysight N8742A is a 600 V, 5.5 A, 3300 W, single output power supply in a small 2U package. It offers flexible AC input options, analog/resistance control of output voltage and current, as well as parallel and series connection of multiple supplies to achieve more output current or voltage respectively.
-
HCL-5000KN+ -
MULTI MEASURING INSTRUMENTS Co., Ltd.
・Wide AC current measurements for 0.01A~500A.・Easy operation, Push to Open and Pull to Disconnect Mechanism.・Safe AC current measurements for high voltage circuit (AC80 to 7000V).・Auto power off function and Splash proof structure.
-
HCL-5000+ -
MULTI MEASURING INSTRUMENTS Co., Ltd.
・Wide AC current measurements for 0.01A~500A.・Easy operation, Push to Open and Pull to Disconnect Mechanism.・Safe AC current measurements for high voltage circuit (AC80 to 7000V).・Auto power off function and Splash proof structure.
-
AC Moving Iron Meter -
Bee Instruments
Moving-iron instruments are generally used to measure alternating voltages and currents. In moving-iron instruments the movable system consists of one or more pieces of specially-shaped soft iron, which are so pivoted as to be acted upon by the magnetic field produced by the current in coil.
-
CM3286 Series -
HIOKI E.E. Corp
Measure power ranging from 5 W at a low current of 60 mA to 360 kW. In addition to current, voltage, and power, measure simple integral power consumption and phase sequence. Discover manipulation of electric meters by comparing meter and integral power consumption measurements. Discover theft by measuring leakage current.
-
PeakTech Prüf- und Messtechnik GmbH
Is a measuring device for AC and DC currents up to 1000 A using a current clamp for conductor diameters up to 48 mm. Current and voltage measurements are carried out as true RMS (true rms value) measurements, which means that the measured values are displayed correctly even with waveforms that deviate from a sine wave.
-
SG5201 -
Shanghai Jiuzhi Electric Co., Ltd.
This instrument offers a complete set of functions to measure and detect effectively all parts of current in an insulation system. The instrument can supply an output power of 5W and a test voltage of up to 5000V and therefore measure insulation resistances up to 1TOhm. Additionally step-up voltage measurement, withstand voltage measurement, AC/DC voltage and frequency measurements up to 600V can be performed.
-
ESDEMC Technology LLC
Pulsed IV-Curve Test and Analysis System is our new development for 2015. It is an advanced and compact pulsed IV-curve characterization system designed to simulate pulsed ESD events such as TLP, vf-TLP, HMM, HBM, EFT, and LV-Surge. It will monitor the transient voltage and current waveform during the pulse in ps or ns segment, and test the pre- and post-pulse status (leakage current, breakdown voltage, biasing current, static IV curve, etc) of the device under test (DUT), such as protection devices, semiconductors, circuit modules, touch panel sensor, etc.
-
CPT 16th Brick Series -
Semiconductor Circuits, Inc.
Open frame sixteenth-brick DC-DC converter that conforms to industry standard specifications (DOSA). The converter operates over an input voltage range of 36 to 75 VDC, and provides a tightly regulated output voltage with an output current rating of 20 A.